Twin Industries    Twin Industries International - Boiler Brokers   International   

Home Page    New Boilers    Reconditioned and Secondhand Boilers    Used Turbines and Generators   
Superheaters    Heat Recovery     New and Secondhand Burners     Miscellaneous Equipment     Contact Details    E-mail


   Used Steam Turbines, Gas Turbines and Generators  

Below is a list of used Steam Turbines, Gas Turbines and Generators currently available

If any are of interest please e-mail us the reference numbers,
together with your full company name, address, contact and telephone and fax numbers.
We will then arrange for a full specification and quote to be sent to you by the supplier.

If the Turbine or Generator you require is not listed we will try and find it for you.




Ref: T34/01/07/A43

Used Tornado, Typhoon and Nomad Gas Turbines available

Ref: T37/02/10/A47

6MW Kaluga Backpressure Steam Turbine

Manufactured 1961
Year of shutdown 1998
Last overhauled 2009
Total hours of operation 163,000 hours
Speed 3000 rpm
Inlet steam temperature 435 deg C
Inlet steam pressure 35 bar
Exhaust steam temperature 306 deg C
Exhaust steam pressure 11 bar
Steam flow 65 tons/hr

c/w Electrosila Generator

Capacity 6000KW
Voltage 6300 V
Frequency 50 hz
Power factor 0.8
Speed 3000 rpm

Ref: T38/02/10/A47

2 x 25MW UTMZ Condensing Steam Turbines

Manufactured 1964/65
Total hours of operation 97,000/87,000 hours
Speed 3000 rpm
Inlet steam temperature 535 deg C
Inlet steam pressure 90 bar
Exhaust regulating steam lead
Steam flow 161 tons/hr

c/w Electrosila Generator

Capacity 25000KW
Voltage 6300 V
Frequency 50 hz
Power factor 0.8
Speed 3000 rpm

Ref: T39/02/10/A47

50MW LMZ Backpressure Steam Turbine

Manufactured 1977
Total hours of operation 40,000 - 50,000 hours
Speed 3000 rpm
Inlet steam temperature 540 deg C
Inlet steam pressure 130 bar
Exhaust steam pressure 13 +/- 3 bar
Steam flow 490 tons/hr

c/w Electrosila Generator

Capacity 6000KW
Voltage 10.5 kV
Frequency 50 hz
Power factor 0.8
Speed 3000 rpm

Ref: T41/07/13/A48

12MW Kaluga Steam Turbine Generator Set

Manufacturer - Kaluga Turbine Plant, Russia
Model PT 12-35/10M
Ser. No 75120
Year of manufacture 1994
Rating 12 MW
RPM 3000
Inlet steam pressure 35 kg/cm2
Inlet steam temp. 435 deg C

Exhaust steam pressure for process purpose 10 kgs/cm2
Exhaust flow for process purpose 50 tph

Exhaust steam pressure for heat-extraction purpose 1,2 kgs/cm2
Exhaust flow for heat-extraction purpose - 40 tph

Assembling Features
Weight of turbine without oil system 33,4 t
Oil tank with auxiliaries 1,3 t
Lower half of turbine shell without diaphragm 7,7 t
Upper half of turbine shell with diaphragm 11,5 t
Turbine rotor 5,7 t

Generator
Type T-12-2UZ
Manufacturer "Privod electromechanic" Ltd, Russia
Ser. No 047/0014
Year of Manufacture 1995
Frequency 50 Hz
Capacity 12 MW
Voltage 6300 V
Rotation frequency 3000 RPM

Excitation Unit
Type BVUG - 21UZ
Nominal capacity - 80 kW
Nominal voltage - 250 D
Nominal current - 320 A
Rotation frequency 3000 RPM

Machinery was started in 1996. Stopped in 2006. Running hours- 60200 h.

Turbine is well maintained. Overhauled in 2005. Located in Ukraine.

Ref: T42/11/13/A28

6250KW Leroy Somer Alternator

Year of manufacture - 1997
Frequency - 50 Hz
Voltage - 11,000 volts
Fully refurbished in 2007, only 5000 hours operation
Location - Germany

Ref: T43/06/16/A46

5.5MW Dresser Rand Steam Turbine

Year of manufacture - 1999
Model - 3S-V4
Power Rating - 5.58MW
Running Hours - 47,339
Nominal Steam Flow - 75 t/h
Inlet - 70 barg / 460 deg C
Outlet - 19 barg /304 deg C
Nominal Speed - 8,000 RPM

Gearbox - Graffenstadden Model TX 50/5C 8000/1500 RPM
Governor - Woodward 505